Face-Scan Vitals — Report

Fit your whole face in the frame and line your forehead up inside the box, in good even light. Estimates pulse, heart-rate variability and a rough blood-pressure band from facial blood-flow color changes (rPPG).

camera off signal
Camera is off. Press “Start scan”.
Not calibrated — blood pressure uses a population baseline.

History

Trends

Not a medical device. Experimental wellness estimates from a consumer camera; they change with lighting, motion and skin tone. Blood pressure is a coarse, uncalibrated estimate — not a cuff replacement. Do not use for diagnosis, medication, or emergencies. If you feel unwell, contact a clinician.
How this works, calibration & accuracy notes
Each frame's average green-channel intensity over your forehead forms a photoplethysmographic (PPG) waveform — haemoglobin absorbs green light, so the signal pulses with your heartbeat. We detrend, band-pass filter to 0.7–4 Hz, and take an FFT; the dominant peak is your pulse. Beat-to-beat intervals give HRV (RMSSD/SDNN). Blood pressure is inferred from HR + HRV features with a transparent heuristic.

Calibration. Take a reading with a real arm cuff, then run a scan and enter the cuff numbers. We store the difference and apply it to future estimates (single-point offset calibration). This personalizes the baseline and is the single biggest accuracy improvement, but it is still an estimate, not a diagnosis. Re-calibrate periodically. History and calibration are stored only in this browser on this device.

Best results: bright, even, flicker-free light; hold still; forehead inside the box; ~40 s scan.